CAD-Server the power generator specialist

CAD-Server Kft. designs, installs and commissions power generators, and maintains them both during and after the warranty period.

Our team of more than 33 well-trained employees covers the design of generator installations as well as the complete mechanical and electrical works.

In every project, we strive to provide our clients with comprehensive, high-quality service. To that end, our service department holds a substantial stock of spare parts, so we can repair the faults most likely to occur using parts from our warehouse in Hungary.

Our goal is to provide our clients with reliable power supply solutions that meet every industrial or commercial need – whether for installation, rental or long-term service.

PARTNERS

  • and 100+ more partners

IN NUMBERS

1990

in business since

33

specialists

1000+

generators maintained

1500+

projects

4–24 hours

on-site response time

4–1400 kVA

own rental fleet

3

service bases nationwide

Budaörs · Kiskunhalas · Tardos

2.6 MW

rental load bank capacity

ISO 9001

quality management · MCERT

ISO 14001

environmental management · MCERT

END-TO-END SERVICE

kVA ESTIMATOR

This block still lives in the earlier prototype; it moves over in the next phase of the component migration.

CUMMINS

Cummins Europe model range · 50 Hz · Bulletin 6614074

61 of 61 models

Cummins diesel generator sets – European model range, 50 Hz. Standby, prime and DCC ratings in kVA and kWe.
STANDBY
rating
PRIME
rating
DCC
rating
C17D5 16.5131512
C22D5 18172016
C22D5Q 22182016
C28D5 27.5222520
C44D5e 44354032
C55D5EQ 55445040
C55D5e 55445040
C66D5EQ 66536048
C330D5EQ 330264300240
C450D5Q 450360409327
C550D5QB 550440500400
C55D5e 55445040
C66D5EQ 66536048
C66D5e 66536048
C90D5 90728265
C110D5Q 1108810080
C110D5 1108810080
C150D5 150120136109
C170D5Q 170136155124
C170D5 170136155124
C175D5e 175140160128
C200D5E 200160182146
C275D5 275220250200
C275D5e 275220250200
C300D5 300240275220
C300D5e 300240275220
C330D5EQ 330264300240
C330D5 330264300240
C330D5e 330264300240
C400D5 400320360288
C400D5eB 400320360288
C450D5Q 450360409327
C450D5 450360409327
C450D5eB 450360409327
C500D5 500400455364
C550D5QB 550440500400
C550D5 550440500400
C640D5 640512582466
C700D5 706565640512640512
C825D5 825660750600750600
C825D5E 825660750600750600
C825D5A 825660750600750600
C900D5 900720820656820656
C1400D5 140011201250100012501000
C1675D5A 167513401500120015001200
C1760D5 176014081600128016001280
C1875D5 187515001700136017001360
C1875D5E 187515001700136017001360
C2000D5B 200016001800144018001440
C2000D5EB 200016001875150018751500
C2000D5 206316501875150018751500
C2250D5 225018002000160020001600
C2250D5E 2250180020001600
C2500D5A 250020002250180022501800
C2750D5BE 275022002500200025002000
C3000D5 300024002750220027502200
C3000D5e 300024002750220027502200
C3500D5 350028003125250031252500
C3500D5e 350028003125250031252500
C3750D5 375030003350268033502680
C3750D5e 375030003350268033502680
Standby
— backup operation during a mains outage
Prime
— continuous operation with variable load
DCC
— Data Center Continuous: continuous operation in data centres
kVA / kWe
— apparent and active power

CUMMINS HyLYZER

HyLYZER is Accelera’s PEM (proton exchange membrane) water electrolysis platform, backed by Cummins Inc. Both models deliver hydrogen at 30 barg without a compressor, and their wide dynamic operating range and fast response suit variable power input from renewable sources. The two differ in installation concept: the HyLYZER 500 is an outdoor containerised system, the HyLYZER 1000 an indoor modular one.

HyLYZER 500

outdoor · containerised
Product photo of the HyLYZER 500

A containerised outdoor system designed for fast, plug-and-play installation.

HyLYZER® is Cummins' globally proven modular water electrolyzer system designed for easy on-site installation inside or out, with simple interconnectivity to scale up, and an unrivaled record for reliability, low maintenance and on-site safety. Recommended for projects between 1,000 - 10,000 Nm3/h.

Nominal power rating
2.5 MW
Hydrogen production
45 kg/h · 500 Nm³/h
Delivery pressure, without a compressor
30 barg (435 psig)
Hydrogen quality
99.999%
Dynamic operating range
7–100%
System-specific consumption
53.2 kWh/kg @ 44.4 kg/h
Installation environment
−20 … 40 °C (outdoor)
Footprint
17 m × 13 m
  • designed for weatherproof outdoor installation
  • transported in containers, with less site preparation
  • factory-tested and pre-commissioned
  • built-in hydrogen detection

HyLYZER 1000

indoor · modular
Product photo of the HyLYZER 1000

An exceptionally compact, modular, skid-mounted system requiring minimal on-site assembly.

HyLYZER® is Cummins' globally proven modular water electrolyzer system designed for easy on-site installation inside or out, with simple interconnectivity to scale up, and an unrivaled record for reliability, low maintenance and on-site safety. Recommended for projects between 1,000 - 10,000 Nm3/h.

Nominal power rating
5 MW
Number of cell stacks
2
Hydrogen production
90 kg/h · 1000 Nm³/h
Delivery pressure, without a compressor
30 barg (435 psig)
Hydrogen quality
99.9% (gas fully saturated with water)
Max. impurities
O₂ < 100 ppm · N₂ < 12 ppm
Dynamic operating range
15–100%
System-specific consumption
52 kWh/kg
Installation environment
5 … 40 °C (indoor)
Footprint – electrolyser
8.4 m × 2.3 m
Footprint – rectifier
13.5 m × 5.1 m
  • minimal on-site assembly
  • two trucks per module for transport
  • reduced land use and simpler plant integration
  • enclosed, ventilated hazardous zones with hydrogen detection

Both models

Compliance and safety

  • ISO 22734 compliant
  • ATEX-proof enclosure
  • ASME/PED certified pressure systems
  • cybersecurity assessment completed

Applications

  • eFuels and hydrogen carriers – synthetic fuels, ammonia
  • industrial use – feedstock, fuel, reducing agent
  • mobility – fuel cell electric vehicles
  • gas pipeline integration – dedicated pipelines, natural gas blending, e-methane

Technical data as published on the manufacturer’s (Accelera) official product pages: HyLYZER 500 – manufacturer specifications · HyLYZER 1000 – manufacturer specifications

CUMMINS BESS

A Battery Energy Storage System (BESS) stores electrical energy for later use: it takes up surplus energy and releases it when it is needed. It responds rapidly to changes in demand and to grid frequency or voltage instability, supports the integration of renewable sources, and provides backup power and microgrid support – on the grid, at commercial and industrial sites, at community scale and at remote, off-grid locations.

Cummins offers preconfigured BESS units from 211–⁠2280 kWh, with plug-and-play functionality for safe, reliable operation.

  1. Charging the charger system conditions surplus AC grid power or DC solar power for charging.
  2. Storage energy is stored electrochemically in the battery cells as DC potential.
  3. Structure cells form packs, packs form modules, and the modules are aggregated and controlled within a containerised energy storage system.
3D model of the Cummins C400B5ZE battery energy storage unit, three-quarter view from the ZeroEmissions end and the door side

C400B5ZE

The interactive view could not be loaded – the image remains visible.

This browser does not support the interactive view (WebGL 2) – the image remains visible.

3D model of the Cummins C2000B5ZE battery energy storage container, three-quarter view from the control end and the door side

C2000B5ZE

The interactive view could not be loaded – the image remains visible.

This browser does not support the interactive view (WebGL 2) – the image remains visible.

  1. Conversion power electronics and inverters manage the energy flow; AC/DC conversion and phase-coupled inverters return the stored energy as grid-synchronised AC where required.
  2. Thermal management and protection thermal management regulates the temperature, while safety mechanisms mitigate the risk of overheating, overcharging and system faults.
  3. Discharge the stored energy is released to meet local or grid-scale demand.

Technical background

More information: Cummins – BESS product page

Types of BESS

The Cummins article distinguishes five technologies. This is a general overview, not a description of specific Cummins units.

  • Lithium-based systems: widely used; high energy density, long deep-cycle life and relatively low maintenance.
  • Flow batteries: energy is held in liquid electrolytes in external tanks; scalable and suited to long-duration, large stationary storage.
  • Lead-acid batteries: established, robust and relatively low-cost, but with lower energy density and a shorter cycle life than newer technologies; used in some backup and smaller off-grid systems.
  • Sodium-sulfur batteries: operate at high temperatures; suited to large-scale applications.
  • Supercapacitors (ultracapacitors): very fast charge and discharge, but lower energy density than batteries; suited to frequent cycling and short-duration smoothing.

Safety and system control

Safety mechanisms are designed to mitigate the risks of overheating, overcharging, over-discharge, thermal runaway, and system faults or emergency conditions. Several functions work together:

  • a battery management system (BMS);
  • thermal management and HVAC cooling, regulating the operating temperature;
  • the BESS controller, providing operational safety control;
  • a fire suppression system.

Applications

  • grid stabilisation and peak-demand management
  • backup power during grid outages
  • integration of intermittent renewable sources
  • support for EV charging
  • lower electricity costs
  • reduced emissions
  • Installation types: off-grid and remote · commercial and industrial · community scale.
  • Cummins also integrates battery storage into broader microgrid solutions.
DSE 7420 MKII – Auto Mains (Utility) Failure Control Module, front view

07 DEEP SEA

CAD-Server is the official Hungarian distributor of Deep Sea Electronics.

  1. DSE 7420 MKII

    Auto Mains (Utility) Failure Control Module

    For single diesel or gas generating sets; monitors the mains (utility) supply as well as the engine. USB, RS232, RS485 and Ethernet ports, SNMP and PLC functionality.

    Overall size (W × H × D)
    250 × 189 × 50.5 mm
    Panel cut-out (W × H)
    220 × 160 mm

    DSE 7420 MKII – manufacturer product page

  2. DSE 8610 MKII

    Synchronising & Load Sharing Auto Start Control Module

    For multi-generator load-share systems, synchronising up to 32 generators. Starts and stops the engine on load demand or fault conditions; 250-event log.

    Overall size (W × H × D)
    245 × 184 × 51 mm
    Panel cut-out (W × H)
    220 × 160 mm

    DSE 8610 MKII – manufacturer product page

  3. DSE 890 MKII

    DSEWebNet® / IoT Gateway - 4G (GSM/Ethernet)

    Remote monitoring of up to five connected DSE controllers via DSEWebNet® or a third-party MQTT broker (MQTT 3.1.1).

    Overall size (W × H × D)
    85.5 × 136.8 × 51 mm

    DSE 890 MKII – manufacturer product page

  4. DSE 335 MKII

    Auto Transfer Switch Control Module

    Monitors the voltage and frequency of two AC supplies – generator, mains (utility) or both; on a source 1 failure it issues a start command to source 2. Timing sequences prevent nuisance starts on short supply breaks.

    Overall size (W × H × D)
    250 × 189 × 50.5 mm
    Panel cut-out (W × H)
    220 × 160 mm

    DSE 335 MKII – manufacturer product page

  5. DSE 9473

    24 volt, 15 amp Intelligent Battery Charger

    Switch-mode charger with charging curves programmable in the DSE Configuration Suite software; DIN rail or chassis mounting. Keeps charging during cranking and running.

    Overall size (W × H × D)
    80 × 205 × 135 mm

    Listed as obsolete by the manufacturer.

    DSE 9473 – manufacturer product page

  6. BC1205

    12 Volt, 5 Amp Battery Charger

    Switch-mode charger with a potentiometer-adjusted charging voltage, suitable for several battery chemistries. DIN rail or chassis mounting, with status LEDs.

    Overall size (W × H × D)
    129.6 × 138.5 × 49 mm

    BC1205 – manufacturer product page

  7. DSE 892

    Simple Network Management Protocol (SNMP) Gateway

    Connects DSE control modules to external SNMP systems, giving full monitoring and control of the connected module's instrumentation and operating state.

    Overall size (W × H × D)
    85 × 149 × 51 mm

    DSE 892 – manufacturer product page

MOSA

MOSA generating sets

RENTAL

4 – 1400 kVA per unit

Request a quote

Our own fleet of diesel generators is available to our clients across this range.

Through our international connections, we can also meet requirements of several tens of MW.

For testing electrical systems, we have load banks for hire with unit ratings of up to 2.6 MW.

Our expert team installs and commissions generators quickly and safely, selecting the most suitable connection point for the building concerned and connecting and disconnecting them professionally.

On request, as well as delivering the generator to site, we provide operating personnel, and with a fuel tank mounted on an off-road truck we guarantee a continuous fuel supply to the generators, even in extreme weather conditions.

SERVICE

SERVICE SUPPORT

We provide service support to our contract customers 24 hours a day.

Our service technicians provide nationwide coverage for the repair and maintenance of machines, both under warranty and after the warranty period.